You are here Incinerator

Incinerator - PD. Karya Mitra Usaha

Incinerator

 Incinerator Cap. : 0.01 m³/hour

Incinerator Cap. : 0.01 m³/hour

Type of Waste   : Medical Waste
Incinerator Capacity   : 0.01 m³/hour
Incinerator Type  : Single Chamber
Operation Time  : 8 hour/day
Chamber Volume   : - 1st Chamber 0.024 m³
Incinerator Dimension (Outter) : L0.47 x W0.32 x H1.67 m
Burner  : 1st Burner 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature  : Chamber ±900°C
Chamber Pressure  : Negatif (Under Atmosferic Pressure)
Exaust Stack      
Diameter : 4 inchi
Height  : ± 2 m.from ground level
Coating  : High Temp. Paint
Refractory Construction     
Fire Brick : Fire Brick SK 32
Castable : CAJ-12
Chamber Insulation    
1st Wall : Fire Brick, SK-32
2nd Wall : Ceramic Fibre, 128 kg/m³
Bottom  : Insulating Brick
Shell & Structure Material Chamber :    
- Shell Plate t.3 mm, Mild Steel    
- Joint Flange t.10 mm     
- Burner Port t.8 mm     
- Structure UNP 80 &     
- Coating : Epoxy Paint     
FDF Blower   : Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement  : 3 kW. 380 V. 3 PH
Fuel : Diesel Oil (Solar)  : Insulating Brick
Fuel Consumption   : Max.10 liter / hour
Fuel Tank :     
- Cap. 10 ltr     
- Material Tank  : Mild Steel plate t. 3 mm     
- Level Control     
- Drain Port     
Control System :     
- ELC     
- Temperature Control : Digital     
- Thermocouple     : Type – K.     
- Limit Switch     
Ash  : 5 – 10 % waste weight
Ash Discharging  : Manual
Feeding System  : Manual
Warranty Term  : One year ( Service)
Operator Requirement  : 1 Person
Area Requirement  : 2 x 3 m

 

Incinerator Cap. : 0.05 m³/hour

Incinerator Cap. : 0.01 m³/hour

Type of Waste : Medical Waste
Incinerator Capacity : 0.025 – 0.05 m³/hour
Incinerator Type : Single Chamber
Operation Time     : 8 hour/day
Chamber Volume    : - 1st Chamber 0.07 m³
Incinerator Dimension (Outter ) : L0.6 x W 0.6x H 1.2 m
Burner     : - 1st Burner 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature : - 1st Chamber 400 - 800°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack     
Diameter : 250 mm
Height    : ± 4 m.from ground level
Coating : High Temp. Paint
Refractory Construction :     
Fire Brick : Fire Brick SK 34
Castable : CAJ-14
Chamber Insulation    
1st Wall : Fire Brick, SK-34
2nd Wall : Ceramic Fibre, 128 kg/m³
Bottom     : Insulating Brick
Shell & Structure Material Chamber :    
- Shell Plate t.3 mm, Mild Steel    
- Joint Flange t.12 mm     
- Burner Port t.8 mm     
- Structure UNP 80 &     
- Coating : Epoxy Paint     
FDF Blower: Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil (Solar)
Fuel Consumption : Max.20 liter / hour
Fuel Tank :     
- Cap. 50 ltr     
- Material Tank : Mild Steel plate t. 3 mm     
- Level Control     
- Drain Port     
Control System :     
- ELC     
- Temperature Control : Digital     
- Thermocouple : Type – K.     
- Limit Switch     
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System  : Manual
Warranty Term  : One year ( Service)
Operator Requirement: 1 Person
Area Requirement : 2 x 3 m

 

 

Incinerator Cap. : 0.3 m³/hour

Incinerator Cap. : 0.01 m³/hour

Type of Waste     : Medical Waste
Incinerator Capacity: 0.3 m³/hour
Incinerator Type : Single Chamber
Operation Time     : 8 hour/day
Chamber Volume    : 1st Chamber 0.35 m³
Incinerator Dimension (Outter ) : L1.22 x W0.96 x H1.12 M
Burner     : -1st Burner 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature : -1st Chamber ±800°C - 1200°C
Chamber Pressure: Negatif (Under Atmosferic Pressure)
Exaust Stack     
Diameter: 250 mm
Height    : ± 4 m.from ground level
Coating : High Temp. Paint
Refractory Construction :     
Fire Brick : Fire Brick SK 32
Castable : CAJ-12
Chamber Insulation    
1st Wall : Fire Brick, SK-32
2nd Wall : Ceramic Fibre, 128 kg/m³
Bottom : Insulating Brick
Shell & Structure Material Chamber :    
- Shell Plate t.3 mm, Mild Steel    
- Joint Flange t.10 mm     
- Burner Port t.8 mm     
- Structure UNP 80 &     
- Coating : Epoxy Paint     
Wet Scrubber :    
Diameter : 0.38 x 0.6 mm    
Material : t,2 mm,stainless     
Spray nozzle    
Spray Pump : ± 20 – 40 liter / menit    
Power : 1 HP / 220 V / 50 Hz    
FDFD Blower: Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement     : 3 kW. 380 V. 3 PH
Fuel : Diesel Oil (Solar)
Fuel Consumption : Max.10 liter / hour
Fuel Tank :     
- Cap. 60 ltr     
- Material Tank : Mild Steel plate t. 3 mm     
- Level Control     
- Drain Port     
Control System :     
- ELC     
- Temperature Control : Digital     
- Thermocouple : Type – K.     
- Limit Switch     
Ash : 5 – 10 % waste weight
Ash Discharging     : Manual
Feeding System     : Manual
Warranty Term     : One year ( Service)
Operator Requirement: 1 Person
Area Requirement : 3 x 3 m

 

Incinerator Cap.20 kg/Hour

Incinerator Cap. : 0.01 m³/hour

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Capacity: 20 kg/hour Multiple Chamber
Incinerator Type : Medical Waste
Operation Time : 8 hour/day
Chamber Volume: 1st Chamber 0.5 m³
Mixing Room : 0.1 m³
Second Chamber : 0.2 m³
Incinerator Dimension (Outter ) : L:1.50 X W:1.2 X H:1.6 m
Burner     : -1st Burner 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature:    
1st Chamber : 600 - 800°C    
2nd Chamber : 800- 1000°C    
Chamber Pressure: Negatif (Under Atmosferic Pressure)
Exaust Stack     
Diameter: 350mm (1st Stack),Ø200 mm (2nd Stack)
Height    : ± 8 m.from ground level
Sampling Port Ø3”     
Coating : High Temp. Paint
Refractory Construction :     
Fire Brick : Fire Brick SK 34
Castable : CAJ-14
Chamber Insulation    
1st Wall : Fire Brick, SK-34
2nd Wall : Ceramic Fibre, 128 kg/m³
3rd Wall : Rockwool,60 kg/m³
4th Wall : Glaswool, 20 kg/m³
5th Wall : Shell Plate
Bottom     : Insulating Brick
Shell & Structure Material Chamber :    
- Shell Plate t.4 mm, Mild Steel    
- Joint Flange t.12 mm     
- Burner Port t.8 mm     
- Plenum Plate t.3 mm    
- Structure UNP 80 & UNP 50    
- Lifter t.12 mm    
- Coating : Epoxy Paint     
FDFD Blower: Sentrifugal ,2500 CMH, 380/50,2800 rpm, 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil (Solar)
Fuel Consumption : Max.15 liter / hour
Fuel Tank :     
- Cap. 250 ltr     
- Material Tank : Mild Steel plate t. 4 mm     
- Level Control     
- Drain Port     
Control System :     
- ELC     
- Temperature Control : Digital     
- Thermocouple : Type – K.     
- Limit Switch     
Ash : 5 – 10 % waste weight
Ash Discharging     : Manual
Feeding System: Manual
Warranty Term : One year ( Service)
Operator Requirement: 1 Person
Area Requirement : 4 x 3 m
Emision Quality    : Smokeless
According to Goverment    : CO < 100 mg/Nm3
Regulation: NO2 < 300 mg/Nm3, Opacity < 10 %

 

Incinerator Cap.30 kg/Hour

Incinerator Cap.30 kg

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Capacity: 30 kg/hour (0,3m³/h)  Multiple Chamber, Retort System
Incinerator Type : Medical Waste
Operation Time : 8 hour/day
Chamber Volume: 1st Chamber 0.5 m³
Mixing Room : 0.1 m³
Second Chamber : 0.2 m³
Incinerator Dimension (Outter ) : L:1.8 X W:1.4 X H:1.6 m
Burner : 1st Burner : 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
2nd Burner : 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperaturess:    
1st Chamber : 600 - 800°C    
2nd Chamber : 800- 1000°C    
Chamber Pressure: Negatif (Under Atmosferic Pressure)
Exaust Stack     
Diameter: 400mm (1st Stack),Ø250 mm (2nd Stack)
Height    : ± 8 m.from ground level
Sampling Port Ø3”     
Coating : High Temp. Paint
Refractory Construction :     
Fire Brick : Fire Brick SK 34
Castable : CAJ-14
Chamber Insulation    
1st Wall : Fire Brick, SK-34
2nd Wall : Ceramic Fibre, 128 kg/m³
3rd Wall : Rockwool,60 kg/m³
4th Wall : Glaswool, 20 kg/m³
5th Wall : Shell Plate
Bottom     : Insulating Brick
Shell & Structure Material Chamber :    
- Shell Plate t.3 mm, Mild Steel    
- Joint Flange t.12 mm     
- Burner Port t.6 mm     
- Plenum Plate t.3 mm    
- Structure UNP 80 & UNP 50    
- Lifter t.12 mm    
- Coating : Epoxy Paint     
FDFD Blower    : Sentrifugal (6-12 mm Aq), 14m³/min, Qty : 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil (Solar)
Fuel Consumption : Max.20 liter / hour
Fuel Tank :     
- Cap. 250 ltr     
- Material Tank : Mild Steel plate t. 3 mm     
- Level Control     
- Drain Port     
Control System :     
- PLC/ELC     
- Temperature Control : Digital     
- Thermocouple : Type – K.     
- Limit Switch     
Ash : 5 – 10 % waste weight
Ash Discharging     : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement: 1 Person
Area Requirement : 5 x 4 m
Emision Quality    : Smokeless
According to Goverment    : CO < 100 mg/Nm3
Regulation: NO2 < 300 mg/Nm3, Opacity < 10 %

 

Incinerator Cap.50 kg/Hour

incinerator-50

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domestic Waste
Incinerator Capacity : 50 kg/hour (0,3m³/h)   Multiple Chamber, Retort System
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 1.7 m³
- Mixing Room : 0.4 m³
- Second Chamber : 1.0 m³
Incinerator Dimension (Outter) : L:2.1 X W:2.0 X H:1.9 m
Burner :
- 1st Burner : 10 – 20 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 10 –20 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
- 1st Chamber : 600 - 900°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
- Diameter : 250mm stainles steel,
- Height : ±8.5 m.from ground level
- Sampling Port Ø3”
- Sampling Platform
Scrubber :
- Diametre : 0.77 mm (Outer)
- Height : 2.9 m (Outer)
Material Scrubber :
- Body Plate : SUS – 304, t.3 mm
- Frame : UNP profile
- Piping : SUS – 304 ø 2”
- Nozzle : ø ½”,Stainless steel
Spray Pump :
- Grundfos,CHI 4-20/750 ltr/hr
- Power : 0.38 kW/1 phase/Multistages/Stainless
Refractory Construction :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
Chamber Insulation :
- 1st Wall : Fire Brick, SK-34
- 2nd Wall : Ceramic Fibre, 128 kg/m³
- 3rd Wall : Rockwool,60 kg/m³
- 4th Wall : Glaswool, 20 kg/m³
- 5th Wall : Shell Plate
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate t.4 mm & 6mm. Mild Steel
- Joint Flange t.12 mm
- Burner Port t.8 mm
- Plenum Plate t.3 mm
- Structure UNP 100 & UNP 80
- Lifter t.16 mm
FDF Blower : Sentrifugal,2500 CMH,2800Rpm,1100 Watt,380/50. 2 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.40 liter / hour
Fuel Tank :
- Cap. 500 ltr
- Material Tank : Mild Steel plate t.3 mm
- Drain Port
Control System : ELC
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 6 x 6 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %

 

Incinerator Cap.100 kg/Hour

incinerator-100

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Medical Waste
Incinerator Capacity : 100 kg/hour (0,3m³/h)   Multiple Chamber, Retort System
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 2.5 m³
- Mixing Room : 0.5 m³
- Second Chamber : 1.2 m³
Incinerator Dimension (Outter) : L:2.5 X W:1.4 X H:2.2 m
Burner :
- 1st Burner : 10 – 15 liter / hour, Light Oil Burner, Qty : 2 unit
- 2nd Burner : 10 –20 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800 - 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
- Diameter : 500mm
- Height : ±10 m.from ground level
- Sampling Port Ø3”
- Sampling Platform
- Lining Castable for insulating.
Refractory Construction :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
Chamber Insulation :
- 1st Wall : Fire Brick, SK-34
- 2nd Wall : Ceramic Fibre, 128 kg/m³
- 3rd Wall : Rockwool,60 kg/m³
- 4th Wall : Glaswool, 20 kg/m³
- 5th Wall : Shell Plate
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate t.4 mm & 6mm. Mild Steel
- Joint Flange t.12 mm
- Burner Port t.8 mm
- Plenum Plate t.3 mm
- Structure UNP 120 & UNP 80
- Lifter t.16 mm
FDF Blower : Sentrifugal,4500 CMH,2800Rpm,2200Watt. Qty : 2 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.40 liter / hour
Fuel Tank :
- Cap. 500 ltr
- Material Tank : Mild Steel plate t.4 mm
- Drain Port
Control System : ELC
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 7 x 5 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %

Web Officer

Kami siap membantu Anda

 

Karya Mitra Usaha

Ruko Taman Yasmin Sektor VI No. 134,
Jl. Ring Road Utara, Curug Mekar, Bogor

  • Tel: (+62) 251-754 3316
  • Fax: (+62) 251-754 3281
  • Email: karyamitrausaha@yahoo.com
  • Website: www.incinerator.co.id